The xy2100 interface is used to send x and y coordinates from the. Hi, the xy2 100 protocol is more or less known and also welldocumented. Command frame according xy2100e specification 8 bit command and 8 bit. E1701d baseboard is an xy2100 scanner card which can be extended by options described below and provides following features. Now, i have an oscilloscope and the companys phone number, but right now im more concerned about how to generate a signal like that.

No tags have been added in a nutshell, open xy2100. The software uses standard file formats and features a wide range of editing tools for easy job creation. Besides the target position the xy2100 enhanced protocol offers the possibility to. So, i need to capture data being sent over this kind of obscure protocol. Xy2100 communications protocol industry standard if this is your first visit, be sure to check out the faq by clicking the link above. Simply connecting the device on the standard xy2100 connector placed on the module, you can use the power of the crio to implement fast pid loops, and custom control strategies driving directly the xy2100 device. Direct material laser marking laser engraving, etching, annealing, etc. Now some companies come up with a new interface and protocol, the sl2100. Readwrite and readonly reentrant lock, condition variable, atomic wraps for boolean, integer, long, and reference. Now some companies come up with a new interface and protocol, the sl2 100.

The xy2 100 interface is used to send x and y coordinates from the controller to the deflection system. It is a serial interface using 20bit works,sent with a speed of 2 mbits or 100 kwordss. Scanmaster api provides access to most of the smd functionality through your own user interface. Xy2 100 protocol interface 74227 freelance job guru. This voltage should not be used for other purposes. Now, i have an oscilloscope and the companys phone number, but right now im more concerned. E1803d allinone scanner controller xy2100, xy2200, xy2. Need the board to provide an interface between a windows xp, 7 pc via usb andor ethernet to output laser marking control signals xy2100 protocol. But although it is industrial standard, i cant find any detailed information on this protocol. This interface is referred to as the smartdirect interface. Windows often associates a default program to each file extension, so that when you doubleclick the file, the program launches automatically. Normal stop j momentary action no reset, no direct q positive opening contact available only with snap action contacts. Im trying to control a laser scanner a raylase superscanld directly using the xy2 100 protocol. Im trying to control a laser scanner a raylase superscanld directly using the xy2100 protocol.

Rather than require position commands at 100 khz, we chose to package commands into a standard protocol based on gcode, which is extensible to larger and more complex scan strategies. Umc4 is a usb bus advanced laser marking card,support digital galvo motor,compatible with xy2 100 protocol. Certifies that this is the approved version of the following thesis. Fatfs module is an open source software to implement fat file system to small embedded systems. Under such case, p3 and pin 9 serve as x channel, and firmware setting should be adjusted accordingly. The smart direct protocol is a xy2100 compatible serial protocol with a clock line clk, a frame for example the dc900 parameter file contents will be copied during. Online xyz grid correction with support for several correction table file formats like scaps. Mm3d after user import the 3d model in stl format, mm3d will paste the drawed graphic on the model surface. When using xy2 100 protocol, a second scan head requires the auxiliary io board. Laser control software solutions cambridge technology. Jul 11, 2017 need a hardware and software developer that is familiar with the beaglebone black hardware.

Pin configuration pin name signal description inout. More details on the xy2100 protocol can be found in other literature shannon. Am gcode is interpreted into xy2100 protocol and sent to the galvo scanners and laser using a custom transmitter. Request pdf on nov 1, 2017, dinh van luan and others published implementation of the xy2100 protocol on lowcost microcontroller find, read and cite all. File extensions tell you what type of file it is, and tell windows what programs can open it. I am currently working on a project which require to generate xy2100 protocol for laser galvo systems. Generating 3d correction files over a surface 3d marking importing 3d vectors via various file formats like. A file extension is the set of three or four characters at the end of a filename. Umc4 builtin full offline marking functions, could access up to 16 files, each file contains up to 8 sets autotext and 8 kinds of fonts. Laser path planning and power control strategies for. Enhanced xy2100 protocol to switch head tuning velocity and position dependent power control 1 thcontrol of 4 axis 1 licence. Has anybody an idea how this protocol looks like and works.

Rdm4024gpci laser marking control system electrical user manual shenzhen ruida technology co. Am gcode is interpreted into xy2 100 protocol and sent to the galvo scanners and laser using a custom transmitter. It is called xy2100, ill attach a document that outlines it. The selection of the protocol depends on the configuration of the laser marking system. Xy2100 is a synchronous serial communication interface specification used for sending position values from a controller to a deflection system 1. In a laser marking system, a laser marking controller should be designed to control several galvanometers through a certain interface using a certain protocol, such as the xy2100 or spi. E1701d baseboard is an xy2 100 scanner card which can be extended by options described below and provides following features.

C mirrors be ftheta lenses yag 100, 160, 163, 254, 330, 420 co2 100, 200, 300 1 settling to within 1% of position 2 single stroke 1 mm characters with f160 lens 3 root. Need a hardware and software developer that is familiar with the beaglebone black hardware. A laser beam interacts with the material to create lines, numbers, a logo or any desired image for easy tracking, precision control and quality tracing. Hi, the xy2100 protocol is more or less known and also welldocumented. This is a free software and is opened for education, research and commercial developments under license policy of.

The spice3 controls up to 2 deflection units via the sl2 100 or rl3 100 protocol with 20 bit position resolution and 10. This allows for system optimization during development an continuous monitoring during operation. It is a serial interface using 20bit words, sent with a speed of 2 mbits or 100 kwordss. Design of a communication interface between the controller. Additionally each axis has a common clock line and data line. When using xy2100 protocol, a second scan head requires the auxiliary io board. Copyright by trevor scott ricker 2017 the university of texas at. Umc4 is a usb bus advanced laser marking card,support digital galvo motor,compatible with xy2100 protocol. It is called xy2 100, ill attach a document that outlines it. The software also has optional support for marking onthefly for webtype applications and zfocus height control for 3d processing. Can be used with any scanhead with xy2 100 or xy2 100 e interface. Contribute to danmcbsaleaexy2100 development by creating an account on github. Mm3d after user import the 3d model in stl format, mm3d will.

The rtc4 series of control boards is available with two different. Need the board to provide an interface between a windows xp, 7 pc via usb andor ethernet to output laser marking control signals xy2 100 protocol. Laser path planning and power control strategies for powder. Minisax controller can be found in the reference manual general scanning industries, 2006. This document describes the iopin configuration, the signal description and the timing specifications. Basically it is made up of four differential pairs. Xy2 100 communications protocol industry standard if this is your first visit, be sure to check out the faq by clicking the link above. Typical digital signal for most of scanner on market. Simply connecting the device on the standard xy2 100 connector placed on the module, you can use the power of the crio to implement fast pid loops, and custom control strategies driving directly the xy2 100 device. Sep 22, 2017 the smart direct protocol is a xy2100 compatible serial protocol with a clock line clk, a frame for example the dc900 parameter file contents will be copied during. Rdm4024gpci laser marking control system electrical user manual. Xy2 100 technical datasheet the xy2 100 interface is used to send x and y coordinates from the controller to the deflection system. Can be used with any scanhead with xy2100 or xy2100e interface.

No tags have been added in a nutshell, open xy2 100. The xy2 100 protocol supports up to three axes of command transfer to the servo controllerss, and provides a means for transferring merged xy status information back to the signal generation controller. This document describes the iopin configuration,the signal description and the timing specifications. Sl2100 interface separate connectors for data and power power in 3pin male dsub connector with high power contacts, type fm3w3p from fctgroup the 3. Cms task management project portfolio management time tracking pdf. Design of a communication interface between the controller and. The xy2100 interface is used to send x and y coordinates from the controller to the deflection system. The actual scan path is compared with the commanded path during controlled tests. I am currently working on a project which require to generate xy2 100 protocol for laser galvo systems.

With xy2100e each axis x, y and also z of the deflection units has a data channel to the head and a data channel back to the control card. Learning management systems learning experience platforms virtual classroom course authoring school administration student information systems. It can log up to 24 million measurements from the deflection unit. Contact cambridge technology to discuss availability of other adapters.